Welcome to eBioscience. Tel: 888.999.1371 or 858.642.2058.  San Diego, California, USA.
Home BestProtocols® Technical Support About Us Contact Us
Clinical Products Research Products Custom Products Weekly New Products

Choose language for TDS:
 

Streptavidin eFluor® 650NC (for FC)

Also known as: SA, Sav

RUO: For Research Use Only
 Streptavidin antibody, eFluor® 650NC conjugateStaining of mouse splenocytes with 0.125 µg of Mouse IgG2b κ Isotype Control Biotin (cat. 13-4732) (blue histogram) or 0.125 µg of Anti-Mouse CD4 Biotin (cat. 13-0041)(purple histogram) followed by Streptavidin eFluor® 650NC (for FC). Total viable cells were used for analysis.
Contents: Streptavidin eFluor® 650NC (for FC)
Catalog Number: 95-4317
Concentration: 5 µl
Formulation: aqueous buffer, 0.09% sodium azide, contains stabilizer if necessary
Storage Conditions: Store at 2-8°C. Light sensitive material. This product is guaranteed for 6 months upon receipt when stored properly.
 
Product Options
Cat. No. Size Price Add Qty to Cart
95-4317-41 25 tests
To view relevant pricing, please select your country and resume browsing.

95-4317-42 100 tests
Note: Several countries will continue to be supplied via distributors. Country specific prices may apply.
 
Research Related Products
Cat. No.Format
00-3222 eFluor® NC Flow Cytometry Staining Buffer
13-0041 Anti-Mouse CD4 Biotin (GK1.5)
13-0049 Anti-Human CD4 Biotin (RPA-T4)
93-4317 Streptavidin eFluor® 605NC (for FC)
 

Available Formats
Cat. No.FormatExcite
(nm)
Emit
(nm)
Reported ApplicationsRegulatory Status
11-4317 Streptavidin FITC 488 518 FC RUO
12-4317 Streptavidin PE 488 575 FC RUO
15-4317 Streptavidin PE-Cy5 488 670 FC RUO
17-4317 Streptavidin APC 633 660 FC RUO
19-4317 Streptavidin Cy5 633 670 FC RUO
25-4317 Streptavidin PE-Cy7 488 760 FC RUO
35-4317 Streptavidin PE-Cy5.5 (See Replacement Formats: PerCP-eFluor® 710 or PerCP-Cy5.5) 488 690 FC RUO
45-4317 Streptavidin PerCP-Cy5.5 488 690 FC RUO
46-4317 Streptavidin PerCP-eFluor® 710 488 710 FC RUO
47-4317 Streptavidin APC-eFluor® 780 633 780 FC RUO
48-4317 Streptavidin eFluor® 450 (Pacific Blue® replacement) 405 450 FC RUO
49-4317 Streptavidin eFluor® 710 633 710 FC RUO
93-4317 Streptavidin eFluor® 605NC (for FC) 350-500 605 FC RUO
94-4317 Streptavidin eFluor® 625NC (for FC) 350-500 625 FC RUO
95-4317 Streptavidin eFluor® 650NC (for FC) 350-500 650 FC RUO
eFluor® products are not offered for sale or use in certain regions. Please contact an eBioscience representative for product availability.
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Alexa Fluor® 647 conjugated products with eFluor® 660 conjugated products.
 
Description
The streptavidin fluorochrome conjugates are commonly used in indirect staining protocols to detect biotinylated primary antibodies in flow cytometry. Streptavidin binds to biotin with high affinity.
Applications Reported
For research use only, not for diagnostic or therapeutic use. eFluor® 650NC Streptavidin has been reported for use in flow cytometric analysis.
Applications Tested
eFluor® 650NC Streptavidin has been pre-titrated and tested by flow cytometric analysis of mouse or human cells using the eFluor® NC Flow Cytometry Staining Buffer (cat. 00-3222). This can be used at 5 μl per test. A test is defined as the amount of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 105 to 108 cells/test.

Laser/Filter Recommendation: When using eFluor 650NC, we recommend excitation with the 405nm violet laser with an appropriate filter set, such as the 630 LP dichroic mirror with the 660/40 bandpass filter. The eFluor 650NC can be minimally excited off of the 633 nm laser, and because its peak emission is 650nm, it will require some compensation out of the APC detector. Please contact eBioscience Technical Support for more information.

Buffer Recommendation: Comparison of eFluor® NC conjugated antibody staining in different buffers has demonstrated that optimal performance is seen with the eFluor® NC Flow Cytometry Staining Buffer (cat. 00-3222). For a comparison of staining with different buffers, refer to eFluor® Nanocrystals page.

For answers to questions about fixation and other FAQs refer to eFluor® Nanocrystal Frequently Asked Questions.

Home  |   Index  |   Site Map  |   FAQ  |   Terms & Conditions  |   Distributors  |   Careers  |   Contact Us
Copyright © 2000-2010 eBioscience, Inc.
Unless indicated otherwise, all products are For Research Use Only. Not for use in diagnostic or therapeutic procedures. Not for further distribution without written consent. Not all products available in all regions.