Staining of mouse splenocytes with 0.125 µg of Mouse IgG2b κ Isotype Control Biotin (cat. 13-4732) (blue histogram) or 0.125 µg of Anti-Mouse CD4 Biotin (cat. 13-0041)(purple histogram) followed by Streptavidin eFluor® 650NC (for FC). Total viable cells were used for analysis.
Contents: Streptavidin eFluor® 650NC (for FC) Catalog Number: 95-4317 Concentration: 5 µl Formulation: aqueous buffer, 0.09% sodium azide, contains stabilizer if necessary Storage Conditions: Store at 2-8°C. Light sensitive material. This product is guaranteed for 6 months upon receipt when stored properly.
Product Options
Cat. No.
Size
Price
Add Qty to Cart
95-4317-41
25 tests
95-4317-42
100 tests
Note: Several countries will continue to be supplied via distributors. Country specific prices may apply.
eFluor® products are not offered for sale or use in certain regions. Please contact an eBioscience representative for product availability.
Flow Cytometry Product Notes: Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size. Fluorochrome Replacements: eBioscience is in the process of replacing all Alexa Fluor® 647 conjugated products with eFluor® 660 conjugated products.
Description
The streptavidin fluorochrome conjugates are commonly used in indirect staining protocols to detect biotinylated primary antibodies in flow cytometry. Streptavidin binds to biotin with high affinity.
Applications Reported
For research use only, not for diagnostic or therapeutic use. eFluor® 650NC Streptavidin has been reported for use in flow cytometric analysis.
Applications Tested
eFluor® 650NC Streptavidin has been pre-titrated and tested by flow cytometric analysis of mouse or human cells using the eFluor® NC Flow Cytometry Staining Buffer (cat. 00-3222). This can be used at 5 μl per test. A test is defined as the amount of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 105 to 108 cells/test.
Laser/Filter Recommendation: When using eFluor 650NC, we recommend excitation with the 405nm violet laser with an appropriate filter set, such as the 630 LP dichroic mirror with the 660/40 bandpass filter. The eFluor 650NC can be minimally excited off of the 633 nm laser, and because its peak emission is 650nm, it will require some compensation out of the APC detector. Please contact eBioscience Technical Support for more information.
Buffer Recommendation: Comparison of eFluor® NC conjugated antibody staining in different buffers has demonstrated that optimal performance is seen with the eFluor® NC Flow Cytometry Staining Buffer (cat. 00-3222). For a comparison of staining with different buffers, refer to eFluor® Nanocrystals page.