Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: eFluorTM 605NC Streptavidin conjugate
Catalog Number: 93-4317
Sizes: 25 tests, 100 tests
Formulation: aqueous buffer, 0.09% sodium azide, contains stabilizer if necessary
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
 
 
data image 1
Staining of mouse splenocyte cells with 0.125 µg of Biotin Mouse IgG2b Iso Cntrl (cat. 13-4732) (blue histogram) or 0.125 µg of Biotin anti-mouse CD4 (GK1.5)(cat. 13-0041)(purple histogram) followed by eFluor 605NC Streptavidin. Total viable cells were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
11-4317 Streptavidin-FITC (Fluorescein isothiocyanate) 488 518 FC 
12-4317 Streptavidin-PE (Phycoerythrin) 488 575 FC 
15-4317 Streptavidin-PE-Cy5 (Phycoerythrin-Cy5) 488 670 FC 
17-4317 Streptavidin Allophycocyanin (SA-APC) 633 660 FC 
19-4317 Streptavidin-Cy5 633 670 FC 
25-4317 Streptavidin-PE-Cy7 (Phycoerythrin-Cy7) 488 760 FC 
35-4317 Streptavidin-PE-Cy5.5 488 690 FC 
45-4317 Streptavidin-PerCP-Cy5.5 (PE-Cy5.5 replacement) 488 690 FC 
93-4317 eFluorTM 605NC Streptavidin conjugate 350-500 605 FC 
94-4317 eFluorTM 625NC Streptavidin conjugate 350-500 625 FC 
95-4317 eFluorTM 650NC Streptavidin 350-500 650 FC 
47-4317 Allophycocyanin-eFluorTM 780 Streptavidin (APC-Alexa Fluor® 750 replacement) 633 780 FC 
48-4317 eFluorTM 450 Streptavidin (Pacific Blue® replacement) 405 450 FC 
49-4317 eFluorTM 710 Streptavidin (APC-Cy5.5 replacement) 633 710 FC 
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

eFluor products are not offered for sale or use in certain regions. Please contact an eBioscience representative for more information on whether our products are available for purchase in your area.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The streptavidin fluorochrome conjugates are commonly used in indirect staining protocols to detect biotinylated primary antibodies in flow cytometry. Streptavidin binds to biotin with high affinity.


Applications Reported


For research use only, not for diagnostic or therapeutic use. eFluor™ 605NC Streptavidin has been reported for use in flow cytometric analysis.


Applications Tested


eFluorTM 605NC Streptavidin has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells using the eFluor NC Flow Cytometry Staining Buffer (cat. 00-3222).

This can be used at 5μL/test (one million cells in a 100μL total staining volume).

Laser/Filter Recommendation: When using eFluorTM 605NC, we recommend excitation with the 405nm violet laser with an appropriate filter set, such as the 595LP dichroic mirror with the 605/40 bandpass filter. An acceptable alternative is the 610/20 bandpass filter. Please contact eBioscience Technical Support for more information.

Buffer Recommendation: Comparison of eFluorTM Nanocrystal conjugated antibody staining in different buffers has demonstrated that optimal performance is seen with the eFluorTM NC Flow Cytometry Staining Buffer (cat. 00-3222). For a comparison of staining with different buffers, click here.

Whole Blood Recommendation: If staining whole blood samples, collection into heparin or sodium citrate-containing tubes is recommended. If EDTA is being used as an anti-coagulant, lysis of RBCs with eBioscience 1X RBC Lysis Buffer (cat. 00-4333) before staining is required.

Click here to view our list of eFluorTM Nanocrystal Frequently Asked Questions.


Related Products


Cat. 13-0048  Biotin anti-human CD4 (clone OKT4 (OKT-4))
Cat. 00-3222  eFluor™ NC Flow Cytometry Staining Buffer



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.