Product Information


Contents: eFluorTM 605NC anti-human CD45RA
Catalog Number: 93-0458
Sizes: 25 tests, 100 tests
Formulation: aqueous buffer, 0.09% sodium azide, contains stabilizer if necessary
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
Clone: HI100
Isotype: Mouse IgG2b, κ
HLDA No.: IV N906
 
 
data image 1
Staining of normal human peripheral blood cells with eFluor™ 605NC Mouse IgG2b Isotype Control (cat. 93-4732) (blue histogram) or eFluor™ 605 NC anti-human CD45RA (HI100) (purple histogram). Cells in the lymphocyte gate were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
14-0458 Affinity Purified anti-human CD45RA N/A N/A FC  IHC 
13-0458 Biotin anti-human CD45RA N/A N/A FC 
11-0458 FITC anti-human CD45RA 488 518 FC 
12-0458 PE anti-human CD45RA 488 575 FC 
15-0458 PE-Cy5 anti-human CD45RA 488 670 FC 
17-0458 Allophycocyanin (APC) anti-human CD45RA 633 660 FC 
25-0458 Phycoerythrin-Cy7 (PE-Cy7) anti-human CD45RA 488 760 FC 
45-0458 PerCP-Cy5.5 anti-human CD45RA (PE-Cy5.5 replacement) 488 690 FC 
93-0458 eFluorTM 605NC anti-human CD45RA 350-500 605 FC 
48-0458 eFluorTM 450 anti-human CD45RA (Pacific Blue® replacement) 405 450 FC 
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

eFluor products are not offered for sale or use in certain regions. Please contact an eBioscience representative for more information on whether our products are available for purchase in your area.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The HI100 monoclonal antibody reacts with human CD45RA, a 220 kDa molecule expressed by subpopulations of CD4+ peripheral T lymphocytes, CD8+ peripheral T lymphocytes, and B cells. The CD45RA+ T cell populations are mainly naive/virgin allowing the use of HI100 mAb as a phenotypic marker to discriminate T cell subsets.


Applications Reported


For research use only, not for diagnostic or therapeutic use. This HI100 antibody has been reported for use in flow cytometric analysis.


Applications Tested


This HI100 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells using eFluorTM NC Flow Cytometry Staining Buffer. This can be used at 5 μl/test (one million cells in a 100μL total staining volume).

The isotype control eFluorTM 605NC mouse IgG2b (cat.93-0458) should be used at 5 μL/test.

Laser/Filter Recommendation: When using eFluorTM 605NC, we recommend excitation with the 405nm violet laser with an appropriate filter set, such as the 595LP dichroic mirror with the 605/40 bandpass filter. An acceptable alternative is the 610/20 bandpass filter. Please contact eBioscience Technical Support for more information.

Buffer Recommendation: Comparison of eFluorTM Nanocrystal conjugated antibody staining in different buffers has demonstrated that optimal performance is seen with the eFluorTM NC Flow Cytometry Staining Buffer (cat. 00-3222). For a comparison of staining with different buffers, click here.

Whole Blood Recommendation: If staining whole blood samples, collection into heparin or sodium citrate-containing tubes is recommended. If EDTA is being used as an anti-coagulant, lysis of RBCs with eBioscience 1X RBC Lysis Buffer (cat. 00-4333) before staining is required.

Click here to view our list of eFluorTM Nanocrystal Frequently Asked Questions.


References



Knapp, W., B. Dorken, et al. eds. (1989). Leucocyte Typing IV: White Cell Differentiation Antigens. Oxford University Press. New York.


Related Products


Cat. 00-3222  eFluor™ NC Flow Cytometry Staining Buffer
Cat. 93-4732  eFluor™ 605NC Mouse IgG2b Isotype Control



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.