Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com |
|
Product Information
Contents: Alexa Fluor® 700 anti-mouse CD62L (L-selectin, LECAM-1, Ly-22)
Catalog Number: 56-0621
Sizes: 25 ug, 100 ug
Formulation: Phosphate buffer pH 7.2, 150 mM NaCl, 0.09% NaN3, 0.1% gelatin
Storage Conditions: Store at 4°C. DO NOT FREEZE. LIGHT-SENSITIVE MATERIAL.
Clone: MEL-14
Isotype: Rat IgG2a, κ
|
|
Staining of BALB/c splenocytes with 0.03 μg of Alexa Fluor® 700 Rat IgG2a Iso Cntrl (cat. 56-4321) (open histogram) or 0.03 μg of Alexa Fluor® 700 anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) (colored histogram). Cells in the lymphocyte gate were used for analysis.
|
| Available Formats of This Product |
| Cat. No. |
Format |
Excite (nm) |
Emit (nm) |
Reported Applications |
| 14-0621 |
Affinity Purified anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
N/A |
N/A |
FA
FC
IHC
IP
|
| 16-0621 |
Functional Grade* Purified anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
N/A |
N/A |
FA
FC
|
| 13-0621 |
Biotin anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
N/A |
N/A |
FC
|
| 11-0621 |
FITC anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
488 |
518 |
FC
|
| 12-0621 |
PE anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
488 |
575 |
FC
|
| 15-0621 |
PE-Cy5 anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
488 |
670 |
FC
|
| 17-0621 |
APC anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
633 |
660 |
FC
|
| 25-0621 |
Phycoerythrin-Cy7 (PE-Cy7) anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
488 |
760 |
FC
|
| 56-0621 |
Alexa Fluor® 700 anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) (APC-Cy5.5 Equivalent) |
633 |
723 |
FC
|
| 57-0621 |
Pacific Blue® anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
402 |
421 |
FC
|
| 45-0621 |
PerCP-Cy5.5 anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) (PE-Cy5.5 replacement) |
488 |
690 |
FC
|
| 93-0621 |
eFluorTM 605NC anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) |
350-500 |
605 |
FC
|
| 47-0621 |
Allophycocyanin-eFluorTM 780 anti-mouse CD62L (L-selectin, LECAM-1, Ly-22) (APC-Alexa Fluor® 750 replacement) |
633 |
780 |
FC
|
*Functional Grade™ (FG™) Purified: Azide-free, sterile-filtered, and endotoxin < 0.001 ng/µg (unless otherwise noted). *Functional Grade™ (FG™) Biotin: Azide-free, sterile-filtered, and endotoxin < 0.05 ng/µg. Purified: Contains azide, not sterile-filtered, and not endotoxin tested. |
Flow Cytometry Product Notes: Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size. Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively. |
Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.
Description
The MEL-14 monoclonal antibody reacts with mouse CD62L, a 76 kDa member of the selectin family. CD62L is expressed by neutrophils, monocytes, and subsets of T, B, and NK cells and binds a number of glycosylated, fucosylated, sulfated sialylated glycoproteins including CD34, glycam-1 and MAdCam-1. These interactions mediate rolling of lymphocytes on activated endothelium at the sites of inflammation and homing of cells to the high endothelial venules (HEV) of peripheral lymphoid tissues.
Applications Reported
For research use only, not for diagnostic or therapeutic use. This MEL-14 antibody has been reported for use in flow cytometric analysis. The Alexa Fluor® 700 emits at 723 nm and can be excited with the He-Ne 633 laser. Most instruments will require a 685 LP mirror and 710/20 filter. Please make sure that your instrument is capable of detecting this fluorochome.
Applications Tested
This MEL-14 antibody has been tested by flow cytometric analysis of mouse splenocyte suspensions. This can be used at less than or equal to 0.06 μg per million cells in a 100 μl total staining volume. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.
References
Gallatin, W. M., I. L. Weissman, et al. (1983). "A cell-surface molecule involved in organ-specific homing of lymphocytes." Nature 304(5921): 30-4. Siegelman, M. H., I. C. Cheng, et al. (1990). "The mouse lymph node homing receptor is identical with the lymphocyte cell surface marker Ly-22: role of the EGF domain in endothelial binding." Cell 61(4): 611-22.
Related Products
Cat. 56-4321 Alexa Fluor® 700 Rat IgG2a Isotype Control (APC-Cy5.5 Equivalent)
Alexa Fluor® and Pacific Blue® are registered trademarks of and licensed under patents assigned to Molecular Probes, Inc. for research use only. This product is subject to an agreement between Molecular Probes, Inc. and eBioscience, and the manufacture, use, sale or import of this product may be subject to one or more U.S. patents, pending applications and corresponding foreign equivalents, owned by Molecular Probes, Inc. (a wholly owned subsidiary of Invitrogen Corp). The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product for life science research or as an ASR. The buyer cannot use this product for manufacturing or for any other screening (specifically including use in combination with microarrays or High Content Screening) or testing purpose, other than as an ASR. For information on purchasing a license to this product for purposes other than life science research or use as an ASR, contact Molecular Probes, Inc.
|
|
Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent. |
|
|