Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: Alexa Fluor® 700 anti-human CD4
Catalog Number: 56-0048
Sizes: 25 tests, 25 ug, 100 ug
Formulation: Phosphate buffered saline, pH 7.2, less than or equal to 0.09% NaN3, BSA and/or gelatin for protein stabilization
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
Clone: OKT4 (OKT-4)
Isotype: Mouse IgG2b
 
 
data image 1 data image 2
Staining of normal human peripheral blood cells with FITC anti-human CD19 (HIB19) (cat. 11-0199) and staining buffer (autofluorescence) (left) or 0.125 μg of Alexa Fluor® 700 anti-human CD4 (OKT4) (right). Cells in the lymphocyte gate were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
14-0048 Affinity Purified anti-human CD4 N/A N/A FC  IP 
16-0048 Functional Grade* Purified anti-human CD4 N/A N/A FC  IP 
13-0048 Biotin anti-human CD4 N/A N/A FC 
11-0048 Fluorescein isothiocyanate (FITC) anti-human CD4 488 518 FC 
12-0048 Phycoerythrin (PE) anti-human CD4 488 575 FC 
17-0048 Allophycocyanin (APC) anti-human CD4 633 660 FC 
35-0048 Phycoerythrin-Cy5.5 (PE-Cy5.5) anti-human CD4 488 690 FC 
51-0048 Alexa Fluor® 647 anti-human CD4 633 668 FC 
53-0048 Alexa Fluor® 488 anti-human CD4 488 519 FC 
56-0048 Alexa Fluor® 700 anti-human CD4 (APC-Cy5.5 Equivalent) 633 723 FC 
57-0048 Pacific Blue® anti-human CD4 402 421 FC 
45-0048 PerCP-Cy5.5 anti-human CD4 (PE-Cy5.5 replacement) 488 690 FC 
93-0048 eFluorTM 605NC anti-human CD4 350-500 605 FC 
*Functional Grade™ (FG™) Purified: Azide-free, sterile-filtered, and endotoxin < 0.001 ng/µg  (unless otherwise noted).
*Functional Grade™ (FG™) Biotin: Azide-free, sterile-filtered, and endotoxin < 0.05 ng/µg.
  Purified: Contains azide, not sterile-filtered, and not endotoxin tested.
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The OKT4 monoclonal antibody reacts with human CD4, a 59 kDa cell surface glycoprotein expressed by the majority of thymocytes, a subpopulation of mature T cells (T-helper cells) and in low levels on monocytes. CD4 is a receptor for the human immunodeficiency virus (HIV). The OKT4 antibody recognizes a different epitope than the RPA-T4 monoclonal antibody, and these antibodies do not cross-block binding to each other's respective epitopes.


Applications Reported


For research use only, not for diagnostic or therapeutic use. This OKT4 (OKT-4) antibody has been reported for use in flow cytometric analysis.

The Alexa Fluor® 700 emits at 723 nm and can be excited with the He-Ne 633 laser. Most instruments will require a 685 LP mirror and 710/20 filter. Please make sure that your instrument is capable of detecting this fluorochome.


Applications Tested


This OKT4 (OKT-4) antibody has been tested by flow cytometric analysis of human peripheral blood leukocytes. This can be used at less than or equal to 0.25 μg per 100 μl blood (or per 1 million cells in 100 μl total staining volume). It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.


References


Reinherz EL, Kung PC, Goldstein G, Schlossman SF. 1979. Separation of functional subsets of human T cells by a monoclonal antibody. Proc Natl Acad Sci. 76(8): 4061-5.

Bour S, Boulerice F, Wainberg MA. Inhibition of gp160 and CD4 maturation in U937 cells after both defective and productive infections by human immunodeficiency virus type 1. J Virol. 1991 Dec;65(12):6387-96. (OKT4, IP, PubMed)


Related Products


Cat. 14-0041  Affinity Purified anti-mouse CD4 (L3T4) (clone GK1.5)
Cat. 19-0041  Cy5 anti-mouse CD4 (L3T4) (clone GK1.5)
Cat. 25-0041  PE-Cy7 anti-mouse CD4 (L3T4) (clone GK1.5)
Cat. 51-0041  Alexa Fluor® 647 anti-mouse CD4 (L3T4) (clone GK1.5)
Cat. 53-0041  Alexa Fluor® 488 anti-mouse CD4 (L3T4) (clone GK1.5)
Cat. 12-0042  PE anti-mouse CD4 (L3T4) (clone RM4-5)
Cat. 56-0042  Alexa Fluor® 700 anti-mouse CD4 (L3T4) (APC-Cy5.5 Equivalent) (clone RM4-5)
Cat. 57-0042  Pacific Blue® anti-mouse CD4 (L3T4) (clone RM4-5)
Cat. 11-0049  FITC anti-human CD4 (clone RPA-T4)
Cat. 13-0049  Biotin anti-human CD4 (clone RPA-T4)
Cat. 16-0049  Functional Grade Purified anti-human CD4 (clone RPA-T4)
Cat. 17-0049  APC anti-human CD4 (clone RPA-T4)
Cat. 27-0049  Allophycocyanin-Alexa Fluor® 750 (APC-Alexa Fluor® 750) anti-human CD4 (APC-Cy7 Equivalent) (clone RPA-T4)
Cat. 56-4732  Alexa Fluor® 700 Mouse IgG2b Isotype Control (APC-Cy5.5 Equivalent)


Alexa Fluor® and Pacific Blue® are registered trademarks of and licensed under patents assigned to Molecular Probes, Inc. for research use only. This product is subject to an agreement between Molecular Probes, Inc. and eBioscience, and the manufacture, use, sale or import of this product may be subject to one or more U.S. patents, pending applications and corresponding foreign equivalents, owned by Molecular Probes, Inc. (a wholly owned subsidiary of Invitrogen Corp). The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product for life science research or as an ASR. The buyer cannot use this product for manufacturing or for any other screening (specifically including use in combination with microarrays or High Content Screening) or testing purpose, other than as an ASR. For information on purchasing a license to this product for purposes other than life science research or use as an ASR, contact Molecular Probes, Inc.



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.