Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: PerCP-Cy5.5 anti-human CD45RA
Catalog Number: 45-0458
Sizes: 25 tests, 100 tests
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3, 0.1% gelatin
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
Clone: HI100
Isotype: Mouse IgG2b, κ
HLDA No.: IV N906
 
 
data image 1
Staining of normal human peripheral blood cells with 0.06 μg of PerCP-Cy5.5 Mouse IgG2b Iso Cntrl (cat. 45-4732) (open histogram) or PerCP-Cy5.5 anti-human CD45RA (HI100) (colored histogram). Cells in the lymphocyte gate were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
11-0458 FITC anti-human CD45RA 488 518 FC 
12-0458 PE anti-human CD45RA 488 575 FC 
13-0458 Biotin anti-human CD45RA N/A N/A FC 
14-0458 Affinity Purified anti-human CD45RA N/A N/A FC  IHC 
15-0458 PE-Cy5 anti-human CD45RA 488 670 FC 
17-0458 Allophycocyanin (APC) anti-human CD45RA 633 660 FC 
25-0458 Phycoerythrin-Cy7 (PE-Cy7) anti-human CD45RA 488 760 FC 
45-0458 PerCP-Cy5.5 anti-human CD45RA 488 690 FC 
57-0458 Pacific Blue® anti-human CD45RA 402 421 FC 

PerCP contained in this product is protected by patents owned by Becton, Dickinson & Company (European patent 0314406, or Japanese Patent JP1888759). This product will not be sold or shipped to customers in France, Germany, Italy, United Kingdom or Japan until the pertinent patents are no longer in effect (October 21, 2008).

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The HI100 monoclonal antibody reacts with human CD45RA, a 220 kDa molecule expressed by subpopulations of CD4+ peripheral T lymphocytes, CD8+ peripheral T lymphocytes, and B cells. The CD45RA+ T cell populations are mainly naive/virgin allowing the use of HI100 mAb as a phenotypic marker to discriminate T cell subsets.


Applications Reported


For research use only, not for diagnostic or therapeutic use. This HI100 antibody has been reported for use in flow cytometric analysis.


Applications Tested


This HI100 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. This can be used at 20 μl (0.06 μg) per million cells in a 100 μl total staining volume.


References



Knapp, W., B. Dorken, et al. eds. (1989). Leucocyte Typing IV: White Cell Differentiation Antigens. Oxford University Press. New York.