Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: Phycoerythrin-Cy5.5 (PE-Cy5.5) anti-human CD45 (LCA)
Catalog Number: 35-0459
Sizes: 25 tests, 100 tests
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
Clone: HI30
Host/Isotype: Mouse IgG1, κ
HLDA No.: IV N816
 
 
human CD45 antibody, Phycoerythrin-Cy5.5 (PE-Cy5.5) conjugate
Surface staining of normal human peripheral blood cells with anti-human CD45 (HI30) PE. Appropriate isotype controls were used (open histogram). Cells in the lymphocyte population were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
11-0459 FITC anti-human CD45 (LCA) 488 518 FC
12-0459 PE anti-human CD45 (LCA) 488 575 FC
13-0459 Biotin anti-human CD45 (LCA) N/A N/A FC
14-0459 Affinity Purified anti-human CD45 (LCA) N/A N/A FC IHC
15-0459 PE-Cy5 anti-human CD45 (LCA) 488 670 FC
17-0459 Allophycocyanin (APC) anti-human CD45 (LCA) 633 660 FC
19-0459 Cy5 anti-human CD45 (LCA) 633 670 FC
25-0459 Phycoerythrin-Cy7 (PE-Cy7) anti-human CD45 (LCA) 488 760 FC
27-0459 DISCONTINUED - Allophycocyanin-Alexa Fluor® 750 (APC-Alexa Fluor® 750) anti-human CD45 (LCA) (APC-Cy7 Equivalent) 633 779 FC
35-0459 Phycoerythrin-Cy5.5 (PE-Cy5.5) anti-human CD45 (LCA) 488 690 FC
45-0459 PerCP-Cy5.5 anti-human CD45 (LCA) (PE-Cy5.5 replacement) 488 690 FC
47-0459 Allophycocyanin-eFluor® 780 anti-human CD45 (LCA) 633 780 FC
48-0459 eFluor® 450 anti-human CD45 (LCA) 405 450 FC
57-0459 DISCONTINUED - Refer to NEW eFluor® 450 anti-human CD45 (Pacific Blue® replacement) (LCA) 402 421 FC
93-0459 eFluor® 605NC anti-human CD45 (LCA) 350-500 605 FC
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The HI30 monoclonal antibody reacts with all isoforms of human CD45, also known as Leukocyte Common Antigen (LCA). CD45 is expressed by all hematopoietic cells excluding circulating erythrocytes and platelets. The cytoplasmic portion of CD45 has tyrosine phosphatase enzymatic activity and plays an important role in activation of lymphocytes.


Applications Reported


For research use only, not for diagnostic or therapeutic use. The HI30 antibody has been reported for use in flow cytometric analysis.

NOTE: eBioscience will be discontinuing all PE-Cy5.5 conjugated antibodies. As an alternative, we recommend that customers use antibodies conjugated to PerCP-Cy5.5, which is a superior fluorochrome due to lesser requirement for compensation. Custom conjugations of PE-Cy5.5 will still be available upon request. Please contact eBioscience Technical Support for additional information.


Applications Tested


The HI30 antibody has been pre-titrated and tested by flow cytometric analysis of human peripheral blood leukocytes. This can be used at 20 μl per 100 μl blood (or per 1 million cells in 100 μl total staining volume).


References



Knapp, W., B. Dorken, et al. eds. (1989). Leucocyte Typing IV: White Cell Differentiation Antigens. Oxford University Press. New York.


Related Products


Cat. 35-4714  Phycoerythrin-Cy5.5 (PE-Cy5.5) Mouse IgG1, K Isotype Control

FOR NON-COMMERCIAL RESEARCH USE ONLY. NOT FOR THERAPEUTIC OR IN VIVO APPLICATIONS. OTHER USE NEEDS LICENSE FROM GE HEALTHCARE BIO-SCIENCES CORP. UNDER U.S. PATENT FOR NON-COMMERCIAL RESEARCH USE ONLY. NOT FOR THERAPEUTIC OR IN VIVO APPLICATIONS. OTHER USE NEEDS LICENSE FROM GE HEALTHCARE BIO-SCIENCES CORP. UNDER U.S. PATENT # 5,268,486, 5,569,587 AND 5,627,027 AND FOREIGN EQUIVALENTS AND PENDING APPLICATIONS.

THIS MATERIAL IS SUBJECT TO PROPRIETARY RIGHTS OF GE HEALTHCARE BIO-SCIENCES CORP. AND CARNEGIE MELLON UNIVERSITY AND MADE AND SOLD UNDER LICENSE FROM GE HEALTHCARE BIO-SCIENCES CORP. THIS PRODUCT IS LICENSED FOR SALE ONLY FOR RESEARCH. IT IS NOT LICENSED FOR ANY OTHER USE. THERE IS NO IMPLIED LICENSE HEREUNDER FOR ANY COMMERCIAL USE.

COMMERCIAL USE shall include:
1. sale, lease, license or other transfer of the material or any material derived or produced from it;
2. sale, lease, license or other grant of rights to use this Material or any material derived or produced from it;
2. use of this material to perform services for a fee for third parties.

IF YOU REQUIRE A COMMERCIAL LICENSE TO USE THIS MATERIAL AND DO NOT HAVE ONE, RETURN THIS MATERIAL, UNOPENED TO EBIOSCIENCE, INC. 10255 SCIENCE CENTER DRIVE, SAN DIEGO, CALIFORNIA 92121 USA AND ANY MONEY PAID FOR THE MATERIAL WILL BE REFUNDED.


Copyright © 2000-2008 eBioscience, Inc.