Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: Functional Grade Purified anti-human CD4 (L3T4)
Catalog Number: 16-0049
Sizes: 50 ug, 500 ug
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, No NaN3
Storage Conditions: Store at 4°C.
Avoid repeated freeze/thaw cycles.
KEEP CONTENTS STERILE.
Endotoxin Level: Less than 0.001 ng/ug antibody, as determined by the LAL assay.
Clone: RPA-T4
Isotype: Mouse IgG1, κ
HLDA No.: IV T114
 
 
data image 1
Profile of functional grade purified mAb RPA-T4 (CD4) staining on human peripheral blood lymphocytes and detection with FITC anti-mouse IgG (cat.no. 11-4011) 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
14-0049 Affinity Purified anti-human CD4 N/A N/A FA  FC  IHC 
16-0049 Functional Grade* Purified anti-human CD4 N/A N/A FA  FC 
13-0049 Biotin anti-human CD4 N/A N/A FC 
11-0049 FITC anti-human CD4 488 518 FC 
12-0049 PE anti-human CD4 488 575 FC 
15-0049 PE-Cy5 anti-human CD4 488 670 FC 
17-0049 APC anti-human CD4 633 660 FC 
25-0049 PE-Cy7 anti-human CD4 488 760 FC 
45-0049 PerCP-Cy5.5 anti-human CD4 (PE-Cy5.5 replacement) 488 690 FC 
95-0049 eFluorTM 650NC anti-human CD4 350-500 650 FC 
47-0049 Allophycocyanin-eFluorTM 780 anti-human CD4 (APC-Alexa Fluor® 750 replacement) 633 780 FC 
48-0049 eFluorTM 450 anti-human CD4 (Pacific Blue® replacement) 405 450 FC 
*Functional Grade™ (FG™) Purified: Azide-free, sterile-filtered, and endotoxin < 0.001 ng/µg  (unless otherwise noted).
*Functional Grade™ (FG™) Biotin: Azide-free, sterile-filtered, and endotoxin < 0.05 ng/µg.
  Purified: Contains azide, not sterile-filtered, and not endotoxin tested.
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The RPA-T4 monoclonal antibody reacts with human CD4, a 59 kDa cell surface receptor expressed by a majority of thymocytes, subpopulation of mature T cells (T-helper cells) and in low levels on monocytes. CD4 is a receptor for the human immunodeficiency virus (HIV). RPA-T4 blocks HIV binding and mixed lymphocyte reaction. The RPA-T4 antibody recognizes a different epitope than the OKT4 monoclonal antibody, and these antibodies do not cross-block binding to each other's respective epitopes.


Applications Reported


For research use only, not for diagnostic or therapeutic use. The RPA-T4 antibody has been reported for use in flow cytometric analysis. RPA-T4 has also been reported for use in blocking of CD4 activity in in vitro functional assays.


Applications Tested


The RPA-T4 antibody has been tested by flow cytometric analysis of human peripheral blood leukocytes. This can be used at less than or equal to 1 μg per 100 μl blood (or per 1 million cells in 100 μl total staining volume). It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.


References



Knapp, W., B. Dorken, et al. eds. (1989). Leucocyte Typing IV: White Cell Differentiation Antigens. Oxford University Press. New York.


Related Products


Cat. 11-4011  FITC Anti-Mouse IgG
Cat. 13-4013  Biotin Anti-Mouse IgG (clone Polyclonal)
Cat. 11-4317  Streptavidin-FITC (Fluorescein isothiocyanate)
Cat. 12-4317  Streptavidin-PE (Phycoerythrin)
Cat. 17-4317  Streptavidin Allophycocyanin (SA-APC)
Cat. 16-4714  Functional Grade Purified Mouse IgG1, K Isotype Control



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.