Welcome to eBioscience. Tel: 888.999.1371 or 858.642.2058.  San Diego, California, USA.
View cart
Account
Ordering help
MSDS
Home BestProtocols™ Technical Support About Us Contact Us
Clinical Products Research Products Custom Products Weekly New Products

Choose language for TDS:
 

Phycoerythrin-Cy5 (PE-Cy5) anti-mouse CD11c (Integrin αX, p150/90)

RUO: For Research Use Only
mouse CD11c antibody, Phycoerythrin-Cy5 (PE-Cy5) conjugatemouse CD11c antibody, Phycoerythrin-Cy5 (PE-Cy5) conjugateStaining of BALB/c splenocytes with FITC anti-mouse/human B220 (RA3-6B2) (cat. 11-0452) and 0.25 μg of PE-Cy5 Golden Syrian Hamster IgG Iso Cntrl (cat. 15-4914) (left) or 0.25 μg PE-Cy5 anti-mouse CD11c (N418) (right). Total cells were used for analysis.
Contents: Phycoerythrin-Cy5 (PE-Cy5) anti-mouse CD11c (Integrin αX, p150/90)
Catalog Number: 15-0114
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3
Clone: N418
Host/Isotype: Armenian Hamster IgG
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
 
Product Options
Cat. No. Size Price Add Qty to Cart
15-0114-81 50 ug
To view relevant pricing, please select your country and resume browsing.

15-0114-82 100 ug
Note: Several countries will continue to be supplied via distributors. Country specific prices may apply.
 
Research Related Products
Cat. No.Format
15-4888 Phycoerythrin-Cy5 (PE-Cy5) Armenian Hamster IgG Isotype Control (eBio299Arm)
 

Available Formats
Cat. No.FormatExcite
(nm)
Emit
(nm)
Reported ApplicationsRegulatory Status
11-0114 FITC anti-mouse CD11c (Integrin aX, p150/90) 488 518 FC RUO
12-0114 PE anti-mouse CD11c (Integrin aX, p150/90) 488 575 FC RUO
13-0114 Biotin anti-mouse CD11c (Integrin aX, p150/90) N/A N/A FC RUO
14-0114 Affinity Purified anti-mouse CD11c (Integrin aX, p150/90) N/A N/A FC IH/F IP RUO
15-0114 Phycoerythrin-Cy5 (PE-Cy5) anti-mouse CD11c (Integrin aX, p150/90) 488 670 FC RUO
16-0114 Functional Grade* Purified anti-mouse CD11c (Integrin aX, p150/90) N/A N/A FC RUO
17-0114 APC anti-mouse CD11c (Integrin aX, p150/90) 633 660 FC RUO
25-0114 Phycoerythrin-Cy7 (PE-Cy7) anti-mouse CD11c (Integrin aX, p150/90) 488 760 FC RUO
35-0114 Phycoerythrin-Cy5.5 (PE-Cy5.5) anti-mouse CD11c (Integrin aX, p150/90) 488 690 FC RUO
45-0114 PerCP-Cy5.5 anti-mouse CD11c (Integrin aX, p150/90) (PE-Cy5.5 replacement) 488 690 FC RUO
47-0114 Allophycocyanin-eFluor® 780 anti-mouse CD11c (Integrin aX, p150/90) (APC-Alexa Fluor® 750 replacement) 633 780 FC RUO
48-0114 eFluor® 450 anti-mouse CD11c (Integrin aX, p150/90) (Pacific Blue® Replacement) 405 450 FC RUO
51-0114 Alexa Fluor® 647 anti-mouse CD11c (Integrin aX, p150/90) 633 668 FC RUO
53-0114 Alexa Fluor® 488 anti-mouse CD11c (Integrin aX, p150/90) 488 519 FC RUO
56-0114 Alexa Fluor® 700 anti-mouse CD11c (Integrin aX, p150/90) (APC-Cy5.5 Equivalent) 633 723 FC RUO
94-0114 eFluor® 625NC anti-mouse CD11c (Integrin aX, p150/90) 350-500 625 FC RUO
*Functional Grade™ (FG™) Purified: Azide-free, sterile-filtered, and endotoxin < 0.001 ng/µg  (unless otherwise noted).
*Functional Grade™ (FG™) Biotin: Azide-free, sterile-filtered, and endotoxin < 0.05 ng/µg.
  Purified: Contains azide, not sterile-filtered, and not endotoxin tested.
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.
 
Description
The N418 monoclonal antibody reacts with mouse CD11c, the integrin αX. CD11c non-covalently associates with β2 integrin to form the CD11c/CD18 heterodimer. CD11c is expressed by dendritic cells, a subset of Intestinal Intraepithelial Lymphocytes (IEL) and some activated T cells. CD11c/CD18 binds to CD54, iC3b and fibrinogen and plays a role in leukocyte adhesive interactions. N418 binds to CD11c on splenic dendritic cells in the T-dependent areas of mouse spleen and precipitates a 150, 90 kDa heterodimer.
Applications Reported
For research use only, not for diagnostic or therapeutic use. The N418 antibody has been reported for use in flow cytometric analysis.
Applications Tested
The N418 antibody has been tested by flow cytometric analysis of mouse splenocyte suspensions. This can be used at less than or equal to 0.5 μg per million cells in a 100 μl total staining volume. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.
References
Xin KQ, Mizukami H, Urabe M, Toda Y, Shinoda K, Yoshida A, Oomura K, Kojima Y, Ichino M, Klinman D, Ozawa K, Okuda K. Induction of robust immune responses against human immunodeficiency virus is supported by the inherent tropism of adeno-associated virus type 5 for dendritic cells. J Virol. 2006 Dec;80(24):11899-910. (N418, FC, PubMed)

Ohteki T, Tada H, Ishida K, Sato T, Maki C, Yamada T, Hamuro J, Koyasu S. Essential roles of DC-derived IL-15 as a mediator of inflammatory responses in vivo. J Exp Med. 2006 Oct 2;203(10):2329-38. (N418, IHC frozen, PubMed)

Zhang J, Kawashima N, Suda H, Nakano Y, Takano Y, Azuma M. The existence of CD11c+ sentinel and F4/80+ interstitial dendritic cells in dental pulp and their dynamics and functional properties. Int Immunol. 2006 Sep;18(9):1375-84. (N418, IHC frozen, PubMed)

Guiducci C, Vicari AP, Sangaletti S, Trinchieri G, Colombo MP. Redirecting in vivo elicited tumor infiltrating macrophages and dendritic cells towards tumor rejection. Cancer Res. 2005 Apr 15;65(8):3437-46. (N418, IHC frozen, PubMed)

Esche C, Gambotto A, Satoh Y, Gerein V, Robbins PD, Watkins SC, Lotze MT, Shurin MR. CD154 inhibits tumor-induced apoptosis in dendritic cells and tumor growth.Eur J Immunol. 1999 Jul;29(7):2148-55.

Finkelman FD, Lees A, Birnbaum R, Gause WC, Morris SC. Dendritic cells can present antigen in vivo in a tolerogenic or immunogenic fashion.J Immunol. 1996 Aug 15;157(4):1406-14.

Crowley MT, Inaba K, Witmer-Pack MD, Gezelter S, Steinman RM. Use of the fluorescence activated cell sorter to enrich dendritic cells from mouse spleen. J Immunol Methods. 1990 Oct 4;133(1):55-66.

Metlay JP, Witmer-Pack MD, Agger R, Crowley MT, Lawless D, Steinman RM. The distinct leukocyte integrins of mouse spleen dendritic cells as identified with new hamster monoclonal antibodies. J Exp Med. 1990 May 1;171(5):1753-71.
Legal
FOR NON-COMMERCIAL RESEARCH USE ONLY. NOT FOR THERAPEUTIC OR IN VIVO APPLICATIONS. OTHER USE NEEDS LICENSE FROM GE HEALTHCARE BIO-SCIENCES CORP. UNDER U.S. PATENT FOR NON-COMMERCIAL RESEARCH USE ONLY. NOT FOR THERAPEUTIC OR IN VIVO APPLICATIONS. OTHER USE NEEDS LICENSE FROM GE HEALTHCARE BIO-SCIENCES CORP. UNDER U.S. PATENT # 5,268,486, 5,569,587 AND 5,627,027 AND FOREIGN EQUIVALENTS AND PENDING APPLICATIONS.

THIS MATERIAL IS SUBJECT TO PROPRIETARY RIGHTS OF GE HEALTHCARE BIO-SCIENCES CORP. AND CARNEGIE MELLON UNIVERSITY AND MADE AND SOLD UNDER LICENSE FROM GE HEALTHCARE BIO-SCIENCES CORP. THIS PRODUCT IS LICENSED FOR SALE ONLY FOR RESEARCH. IT IS NOT LICENSED FOR ANY OTHER USE. THERE IS NO IMPLIED LICENSE HEREUNDER FOR ANY COMMERCIAL USE.

COMMERCIAL USE shall include:
1. sale, lease, license or other transfer of the material or any material derived or produced from it;
2. sale, lease, license or other grant of rights to use this Material or any material derived or produced from it;
2. use of this material to perform services for a fee for third parties.

IF YOU REQUIRE A COMMERCIAL LICENSE TO USE THIS MATERIAL AND DO NOT HAVE ONE, RETURN THIS MATERIAL, UNOPENED TO EBIOSCIENCE, INC. 10255 SCIENCE CENTER DRIVE, SAN DIEGO, CALIFORNIA 92121 USA AND ANY MONEY PAID FOR THE MATERIAL WILL BE REFUNDED.

Home  |   Index  |   Site Map  |   FAQ  |   Terms & Conditions  |   Distributors  |   Careers  |   Contact Us
Copyright © 2000-2009 eBioscience, Inc.
For research use only unless indicated otherwise. Not for further distribution without written consent.