Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: Biotin anti-human CD45RA
Catalog Number: 13-9979
Sizes: 25 ug, 100 ug
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
Clone: JS-83
Isotype: Mouse IgG1, κ
HLDA No.: N/A
 
 
data image 1
Surface staining of normal human peripheral blood cells with anti-human CD45RA (JS-83) FITC. Appropriate isotype controls were used (open histogram). Cells in the lymphocyte population were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
14-9979 Affinity Purified anti-human CD45RA N/A N/A FC 
13-9979 Biotin anti-human CD45RA N/A N/A FC 
11-9979 FITC anti-human CD45RA 488 518 FC 
12-9979 PE anti-human CD45RA 488 575 FC 
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The JS-83 monoclonal antibody reacts with human CD45RA, a 220 kDa molecule expressed by subpopulations of CD4+ peripheral T lymphocytes, CD8+ peripheral T lymphocytes, and B cells. The CD45RA+ T cell populations are mainly naive/virgin allowing the use of JS-83 mAb as a phenotypic marker to discriminate T cell subsets.


Applications Reported


For research use only, not for diagnostic or therapeutic use. JS-83 has been reported for use in flow cytometric analysis.


Applications Tested


This JS-83 antibody has been tested by flow cytometric analysis of human peripheral blood leukocytes. This can be used at less than or equal to 0.5 μg per million cells in a 100 μl total staining volume. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.


References



Knapp, W., B. Dorken, et al. eds. (1989). Leucocyte Typing IV: White Cell Differentiation Antigens. Oxford University Press. New York.


Related Products


Cat. 11-0458  FITC anti-human CD45RA (clone HI100)
Cat. 12-0458  PE anti-human CD45RA (clone HI100)
Cat. 13-0458  Biotin anti-human CD45RA (clone HI100)
Cat. 14-0458  Affinity Purified anti-human CD45RA (clone HI100)
Cat. 15-0458  PE-Cy5 anti-human CD45RA (clone HI100)
Cat. 11-4317  Streptavidin-FITC (Fluorescein isothiocyanate)
Cat. 12-4317  Streptavidin-PE (Phycoerythrin)
Cat. 17-4317  Streptavidin Allophycocyanin (SA-APC)
Cat. 13-4714  Biotin Mouse IgG1, K Isotype Control



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.