Staining of normal human peripheral blood cells with Anti-Human CD3 APC (cat. 17-0038) and Mouse IgG1 κ Isotype Control PE (cat. 12-4714) (left) or Anti-Human CD195 (CCR5) PE (right). Cells in the lymphocyte gate were used for analysis
Contents: Anti-Human CD195 (CCR5) PE Catalog Number: 12-1957 Concentration: 20 μl (0.125 μg)/test Formulation: Phosphate buffered saline, pH 7.2, less than or equal to 0.09% NaN3, BSA and/or gelatin for protein stabilization Storage Conditions: Store at 2-8°C. Do not freeze. Light sensitive material. Clone: eBioT21/8 (T21/8) Host/Isotype: Mouse IgG1, κ
Product Options
Cat. No.
Size
Price
Add Qty to Cart
12-1957-71
25 tests
12-1957-73
100 tests
Note: Several countries will continue to be supplied via distributors. Country specific prices may apply.
Flow Cytometry Product Notes: Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size. Fluorochrome Replacements: eBioscience is in the process of replacing all Alexa Fluor® 647 conjugated products with eFluor® 660 conjugated products.
Description
The eBioT21/8 monoclonal antibody reacts with the amino terminus of human CCR5 (CD195), an approximately 45 kDa member of the G protein-coupled receptor (GPCR) superfamily that binds chemokines including MIP-1α, MIP-1β and RANTES. Human CCR5 is expressed on resting T cells with a memory/effector phenotype, monocytes, macrophages and immature dendritic cells. CCR5 functions as a receptor to direct the chemotaxis of lymphocytes, and is the primary co-receptor for macrophage-tropic Human Immunodeficiency Virus Type 1 (HIV-1), which binds CCR5 through gp120. Binding of the eBioT21/8 monoclonal antibody displays donor variability and may be affected by sub-optimal staining conditions.
Applications Reported
For research use only, not for diagnostic or therapeutic use. This eBioT21/8 (T21/8) antibody has been reported for use in flow cytometric analysis.
Applications Tested
This eBioT21/8 (T21/8) antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. This can be used at 20 μl (0.125 μg)/per test. A test is defined as the amount (μg)/test of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 105 to 108 cells/test.
References
Pollok-Kopp B, Schwarze K, Baradari VK, Oppermann M.
Analysis of ligand-stimulated CC chemokine receptor 5 (CCR5) phosphorylation in intact cells using phosphosite-specific antibodies.
J Biol Chem. 2003 Jan 24;278(4):2190-8. (eBioT21/8, ELISA, IHC, PubMed)
Deng H, Liu R, Ellmeier W, Choe S, Unutmaz D, Burkhart M, Di Marzio P, Marmon S, Sutton RE, Hill CM, Davis CB, Peiper SC, Schall TJ, Littman DR, Landau NR.
Identification of a major co-receptor for primary isolates of HIV-1.
Nature. 1996 Jun 20;381(6584):661-6.
Raport CJ, Gosling J, Schweickart VL, Gray PW, Charo IF.
Molecular cloning and functional characterization of a novel human CC chemokine receptor (CCR5) for RANTES, MIP-1beta, and MIP-1alpha.
J Biol Chem. 1996 Jul 19;271(29):17161-6.