Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: Phycoerythrin (PE) anti-human CD116 (GM-CSFRα)
Catalog Number: 12-1169
Sizes: 25 tests, 100 tests
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3, 0.2% BSA
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
Clone: 4H1
Isotype: Mouse IgG1, κ
HLDA No.: N/A
 
 
data image 1
Staining of normal human peripheral blood cells with PE mouse IgG1 isotype control (cat. 12-4719) (open histogram) or PE 4H1 (colored histogram). Cells in the monocyte gate were used for analysis. 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
14-1169 Affinity Purified anti-human CD116 (GM-CSFR alpha) N/A N/A FC 
13-1169 Biotin anti-human CD116 (GM-CSFR alpha) N/A N/A FC 
11-1169 FITC anti-human CD116 (GM-CSFR alpha) 488 518 FC 
12-1169 PE anti-human CD116 (GM-CSFR alpha) 488 575 FC 
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The 4H1 monoclonal antibody reacts with the human CD116 molecule, the α subunit of GM-CSF receptor. The α subunit associates with the common β chain (CD131) to form the high affinity receptor for GM-CSF. The GM-CSFR α chain is expressed by granulocytes, monocytes, endothelial cells, fibroblasts and some tumor cells.


Applications Reported


For research use only, not for diagnostic or therapeutic use. 4H1 has been reported for use in flow cytometric analysis.


Applications Tested


The 4H1 antibody has been pre-titrated and tested by flow cytometric analysis of human peripheral blood leukocytes. This can be used at 20 μl (0.5 μg) per 100 μl blood (or per 1 million cells in 100 μl total staining volume).


References



Sun, Q., K. Jones, et al. (1999). Simultaneous antagonism of interleukin-5, granulocyte-macrophage colony-stimulating factor, and interleukin-3 stimulation of human eosinophils by targetting the common cytokine binding site of their receptors. Blood 94(6): 1943-51.
Woodcock, J. M., B. J. McClure, et al. (1997). The human granulocyte-macrophage colony-stimulating factor (GM-CSF) receptor exists as a preformed receptor complex that can be activated by GM-CSF, interleukin-3, or interleukin-5. Blood 90(8): 3005-17.
Lopez, A. F., M. A. Vadas, et al. (1991). Interleukin-5, interleukin-3, and granulocyte-macrophage colony-stimulating factor cross-compete for binding to cell surface receptors on human eosinophils. J Biol Chem 266(36): 24741-7.


Related Products


Cat. 12-4714  Phycoerythrin (PE) Mouse IgG1, K Isotype Control



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.