Welcome to eBioscience. Tel: 888.999.1371 or 858.642.2058.  San Diego, California, USA.
View cart
Account
Ordering help
MSDS
Home Products Protocols Technical Support About Us Contact Us

Fluorescein isothiocyanate (FITC) Streptavidin

 
Print Page 
 
Adobe PDF  
Contents: Fluorescein isothiocyanate (FITC) Streptavidin
Catalog Number: 11-4317
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.

Product OptionsPrice
Cat. No.Size

To view relevant pricing,
please select your country
and resume browsing.

11-4317-87 250 ug


   

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
11-4317 Streptavidin-FITC (Fluorescein isothiocyanate) 488 518 FC 
12-4317 Streptavidin-PE (Phycoerythrin) 488 575 FC 
15-4317 Streptavidin-PE-Cy5 (Phycoerythrin-Cy5) 488 670 FC 
17-4317 Streptavidin Allophycocyanin (SA-APC) 633 660 FC 
19-4317 Streptavidin-Cy5 633 670 FC 
25-4317 Streptavidin-PE-Cy7 (Phycoerythrin-Cy7) 488 760 FC 
35-4317 Streptavidin-PE-Cy5.5 488 690 FC 
45-4317 Streptavidin-PerCP-Cy5.5 (PE-Cy5.5 replacement) 488 690 FC 
93-4317 eFluorTM 605NC Streptavidin conjugate 350-500 605 FC 
94-4317 eFluorTM 625NC Streptavidin conjugate 350-500 625 FC 
95-4317 eFluorTM 650NC Streptavidin 350-500 650 FC 
47-4317 Allophycocyanin-eFluorTM 780 Streptavidin (APC-Alexa Fluor® 750 replacement) 633 780 FC 
48-4317 eFluorTM 450 Streptavidin (Pacific Blue® replacement) 405 450 FC 
49-4317 eFluorTM 710 Streptavidin (APC-Cy5.5 replacement) 633 710 FC 
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.


Description


The streptavidin fluorochrome conjugates are commonly used in indirect staining protocols to detect biotinylated primary antibodies in flow cytometry. Streptavidin binds to biotin with high affinity.


Applications Reported


For research use only, not for diagnostic or therapeutic use. Streptavidin-FITC has been reported for use in flow cytometric analysis.


Applications Tested


This lot of SAV-FITC has been tested by flow cytometric analysis to detect biotinylated primary antibodies and can be used at less than or equal to 1 µg/million cells. It is recommended that this reagent be carefully titrated for optimal performance in the assay of interest.


Home  |   Index  |   Site Map  |   FAQ  |   Terms & Conditions  |   Distributors  |   Careers  |   Contact Us
Copyright © 2000-2009 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.