Welcome to eBioscience   Tel: 888.999.1371 or 858.642.2058
Fax: 858.642.2046
Web: www.ebioscience.com
E-mail: info@ebioscience.com

Product Information


Contents: Fluorescein isothiocyanate (FITC) anti-human CD49b (Integrin alpha 2)
Catalog Number: 11-0498
Sizes: 25 tests, 100 tests
Formulation: Phosphate buffer pH 7.2,
150 mM NaCl, 0.09% NaN3, 0.2% BSA
Storage Conditions: Store at 4°C.
DO NOT FREEZE.
LIGHT-SENSITIVE MATERIAL.
Clone: eBioY418 (Y418)
Isotype: Mouse IgG1, κ
 
 

 

Available Formats of This Product
Cat. No. Format Excite
(nm)
Emit
(nm)
Reported Applications
14-0498 Affinity Purified anti-human CD49b (Integrin alpha 2) N/A N/A FC 
16-0498 Functional Grade* Purified anti-human CD49b (Integrin alpha 2) N/A N/A FA  FC 
11-0498 Fluorescein isothiocyanate (FITC) anti-human CD49b (Integrin alpha 2) 488 518 FC 
*Functional Grade™ (FG™) Purified: Azide-free, sterile-filtered, and endotoxin < 0.001 ng/µg  (unless otherwise noted).
*Functional Grade™ (FG™) Biotin: Azide-free, sterile-filtered, and endotoxin < 0.05 ng/µg.
  Purified: Contains azide, not sterile-filtered, and not endotoxin tested.
Flow Cytometry Product Notes:
Test Sizes: To accommodate multicolor flow cytometry, eBioscience is in the process of reducing test size volumes from 20 µl to 5 µl. Please check your antibody vial for the recommended test size.
Fluorochrome Replacements: eBioscience is in the process of replacing all Pacific Blue® and APC-Alexa Fluor® 750 conjugated products with eFluor™ 450 and APC-eFluor™ 780 conjugated products, respectively.

Custom Product Requests
Need a custom product? Download the Custom Product Request Form and submit completed form to customs@ebioscience.com.

Questions? Please consult our answers to frequently asked questions at http://www.ebioscience.com/faq.

Description


The eBioY418 monoclonal antibody reacts with human CD49b, the 150 kDa integrin α2 subunit. The complex of CD49b non-covalently associated with integrin β1 (CD29), also known as VLA-2, is a receptor for collagen and laminin. This complex is expressed by lymphocytes, activated T cells, monocytes and platelets.


Applications Reported


For research use only, not for diagnostic or therapeutic use. This eBioY418 antibody has been reported for use in flow cytometric analysis.


Applications Tested


This eBioY418 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood. This can be used at 20 μl (.125 μg) per 100 μl blood (or per 1 million cells in 100 μl total staining volume).


Related Products


Cat. 11-4714  Fluorescein isothiocyanate (FITC) Mouse IgG1, K Isotype Control



Copyright © 2000-2008 eBioscience, Inc.
For Research Use Only. Not for use in diagnostic procedures. Not for further distribution without written consent.